T1 - Accuracy of the EASI 12-lead electrocardiogram compared to the standard 12-lead electrocardiogram for diagnosing multiple cardiac abnormalities
AU - Drew, Barbara J.
AU - Pelter, Michele M.
AU - Wung, Shu Fen
AU - Adams, Mary G.
AU - Taylor, Carrie
AU - Evans, G. Thomas
AU - Foster, Elyse
N1 - Funding Information:
Supported by awards from the Department of Health & Human Services, National Institute of Nursing Research (ROINR03436), Hewlett-Packard Co., and Zymed Inc. Reprint requests: Barbara J. Drew, PhD, RN, School of Nursing, N6I 1Y, University of California San Francisco, 521 Parnassuss Avenue, San Francisco, CA 94143-0610. Copyright © 1999 by Churchill Livingstone ® 0022 -0736/99/320S -0009510.00/0
PY - 1999
Y1 - 1999
N2 - This study was performed to compare a derived 12-lead electrocardiogram (ECG) using a simple 5-electrode lead configuration (EASI 12-lead) with the standard ECG for multiple cardiac diagnoses. Accurate diagnosis of arrhythmias and ischemia often require analysis of multiple (ideally, 12) ECG leads; however, continuous 12-lead monitoring is impractical in hospital settings. EASI and standard ECGs were compared in 540 patients, 426 of whom also had continuous 12-lead ST segment monitoring with both lead methods. Independent standards relative to a correct diagnosis were used whenever possible, for example, echocardiographic data for chamber enlargement- hypertrophy, and troponin levels for acute infarction. Percent agreement between the 2 methods were: cardiac rhythm, 100%; chamber enlargement- hypertrophy, 84%-99%; right and left bundle branch block, 95% and 97%, respectively; left anterior and posterior fascicular block, 97% and 99%, respectively; prior anterior and inferior infarction, 95% and 92%, respectively. There was very little variation between the 2 lead methods in cardiac interval measurements; however, there was more variation in P, QRS, and T-wave axes. Of the 426 patients with ST monitoring, 138 patients had a total of 238 ST events (26, acute infarction; 62, angioplasty-induced ischemia; 150, spontaneous transient ischemia). There was 100% agreement between the 2 methods for acute infarction, 95% agreement for angioplasty- induced ischemia, and 89% agreement for transient ischemia. EASI and standard 12-lead ECGs are comparable for multiple cardiac diagnoses; however, serial ECG changes (eg, T-wave changes) should be assessed using one consistent 12- lead method.
AB - This study was performed to compare a derived 12-lead electrocardiogram (ECG) using a simple 5-electrode lead configuration (EASI 12-lead) with the standard ECG for multiple cardiac diagnoses. Accurate diagnosis of arrhythmias and ischemia often require analysis of multiple (ideally, 12) ECG leads; however, continuous 12-lead monitoring is impractical in hospital settings. EASI and standard ECGs were compared in 540 patients, 426 of whom also had continuous 12-lead ST segment monitoring with both lead methods. Independent standards relative to a correct diagnosis were used whenever possible, for example, echocardiographic data for chamber enlargement- hypertrophy, and troponin levels for acute infarction. Percent agreement between the 2 methods were: cardiac rhythm, 100%; chamber enlargement- hypertrophy, 84%-99%; right and left bundle branch block, 95% and 97%, respectively; left anterior and posterior fascicular block, 97% and 99%, respectively; prior anterior and inferior infarction, 95% and 92%, respectively. There was very little variation between the 2 lead methods in cardiac interval measurements; however, there was more variation in P, QRS, and T-wave axes. Of the 426 patients with ST monitoring, 138 patients had a total of 238 ST events (26, acute infarction; 62, angioplasty-induced ischemia; 150, spontaneous transient ischemia). There was 100% agreement between the 2 methods for acute infarction, 95% agreement for angioplasty- induced ischemia, and 89% agreement for transient ischemia. EASI and standard 12-lead ECGs are comparable for multiple cardiac diagnoses; however, serial ECG changes (eg, T-wave changes) should be assessed using one consistent 12- lead method.
KW - Electrocardiogram
KW - Myocardial ischemia
KW - Physiologic monitoring
KW - ST segments
UR - http://www.scopus.com/inward/record.url?scp=0033389498&partnerID=8YFLogxK
UR - http://www.scopus.com/inward/citedby.url?scp=0033389498&partnerID=8YFLogxK
U2 - 10.1016/S0022-0736(99)90033-X
DO - 10.1016/S0022-0736(99)90033-X
M3 - Article
C2 - 10688301
AN - SCOPUS:0033389498
SN - 0022-0736
VL - 32
SP - 38
EP - 47
JO - Journal of Electrocardiology
JF - Journal of Electrocardiology
IS - SUPPL.
ER -