Skip to main navigation Skip to search Skip to main content

A validated simple model to predict coexistent coronary disease in patients undergoing mitral valve surgery

  • Eric Lim
  • , Ayyaz Ali
  • , Zain Khalpey
  • , Hutan Ashrafian
  • , Christopher Jackson
  • , Ziad Ali
  • , Themis Chamageorgakis
  • , Francis Wells
  • , John Pepper
  • , Anthony Desouza
  • , Neil Moat

Research output: Contribution to journalArticlepeer-review

Abstract

Objective: The primary limitation of the American Heart Association/American College of Cardiology guidelines is specificity. To improve the selection process, we proposed a simple additive model including age (1 point for every 5 years above 50), male sex (2 points), hypercholesterolemia (2 points), angina (3 points), and electrocardiographic evidence of ischemia (3 points). We recommend screening angiography at 3 or more points. This model was previously derived from 359 patients at Papworth Hospital. Methods: The validation cohort was a consecutive series of patients who underwent mitral valve surgery at the Royal Brompton Hospital. Preoperative coronary angiography reports were obtained, and coronary disease was defined as luminal narrowing of 50% in 2 or more views. Sensitivities and specificities were calculated for the American Heart Association/American College of Cardiology criteria, the simple additive model, and a logistic regression model. Receiver operating characteristic curves were used to validate accuracy and compare discrimination with logistic regression. Results: From 1998 through 2003, angiographic details were available for 342 (86%) of 396 patients who underwent mitral valve surgery. The sensitivity and specificity of the American Heart Association/American College of Cardiology guidelines were 100% and 5%, respectively; those of the simple additive model were 91% and 44%, respectively; and those of logistic regression were 93% and 41%, respectively. The receiver operating characteristic areas for the simple additive and logistic regression model were 0.78 (95% confidence interval, 0.73-0.84) and 0.80 (95% confidence interval, 0.74-0.85), respectively. Conclusions: This is the third independent cohort to highlight the poor specificity of the American Heart Association/American College of Cardiology guidelines. Although high sensitivity is achieved, the cost is the majority of patients requiring screening angiography. Our validated simple model improved the specificity and selection; however, this was achieved at the expense of decreased sensitivity.

Original languageEnglish (US)
Pages (from-to)1318-1321
Number of pages4
JournalJournal of Thoracic and Cardiovascular Surgery
Volume129
Issue number6
DOIs
StatePublished - Jun 2005
Externally publishedYes

ASJC Scopus subject areas

  • Surgery
  • Pulmonary and Respiratory Medicine
  • Cardiology and Cardiovascular Medicine

Fingerprint

Dive into the research topics of 'A validated simple model to predict coexistent coronary disease in patients undergoing mitral valve surgery'. Together they form a unique fingerprint.

Cite this